This walkthrough shows how SPT correlations software turns raw blow counts into design values, using the demo project that installs with DartiGeo.
THE SCENARIO
One borehole has eight SPT tests, from 1.50 m down to 16.50 m. A 1.50 m square footing at the 1.50 m level must not settle more than 25 mm. The engineer needs corrected blow counts, a friction angle, an allowable bearing pressure from published methods, and a record of every assumption.
STEP 1: DEFINE THE SOIL MODEL
On the SPT Input tab, the soil is entered as four layers:
Thickness (m) | Unit weight (kN/m3) | Type | OCR | Uniformity Cu
4.00 | 17.00 | Coarse | 1.00 | 5.00
2.00 | 17.00 | Coarse | 1.00 | 5.00
7.00 | 17.00 | Fine | 1.00 | 5.00
5.00 | 17.00 | Fine | 1.00 | 5.00
The Coarse and Fine labels matter. They tell DartiGeo which correlations apply, so the top 6 m use sand methods and the rest use clay methods.
STEP 2: SET THE FOOTING AND DESIGN LIMITS
- Footing width B = L = 1.50 m
- Allowable settlement 25 mm
- Factor of safety 3.00
STEP 3: SET THE SPT CORRECTIONS
- Energy: 60%
- Borehole diameter: 65 to 115 mm
- Sampler: without liner
- Rod length above the borehole: 1.00 m
- Overburden correction: Liao and Whitman (1986)
- Water level correction: off
- Groundwater level: 7.20 m
STEP 4: ENTER THE BLOW COUNTS
DartiGeo calculates the correction columns automatically:
Depth (m) | N | C | Cn | N60 | (N1)60
1.50 | 17 | 0.75 | 1.70 | 13 | 22
3.00 | 21 | 0.85 | 1.39 | 18 | 25
4.50 | 21 | 0.85 | 1.13 | 18 | 20
6.00 | 17 | 0.95 | 0.98 | 16 | 16
9.00 | 29 | 0.95 | 0.85 | 28 | 24
12.00 | 35 | 1.00 | 0.79 | 35 | 28
15.00 | 30 | 1.00 | 0.74 | 30 | 22
16.50 | 21 | 1.00 | 0.72 | 21 | 15
STEP 5: UNDERSTAND THE CORRECTIONS
At 1.50 m:
- The energy, borehole and sampler factors are all 1.00 in this setup, so C reduces to the rod-length factor, 0.75.
- N60 = 0.75 x 17 = 12.75, shown as 13.
- The effective overburden stress is 17 x 1.50 = 25.5 kPa. At this shallow depth the bare Liao and Whitman expression would give about 2.0, but DartiGeo shows Cn = 1.70 Because it limits the maximum value of Cn to 1.70.
- (N1)60 = 1.70 x 12.75, about 22.
At 9.00 m, the soil is below the 7.20 m water table, so the effective stress is reduced for buoyancy: 17 x 9.00 – 9.81 x 1.80 = 135 kPa. That gives Cn of about 0.85, as shown.
The size of the correction is the lesson. The raw count at 1.50 m is 17, but the normalised value is 22 (+29%). At 16.50 m the raw count is 21 and the normalised value is 15 (-29%). Using raw N would overestimate density at depth and underestimate it near the surface.
STEP 6: READ THE PLOTS
The Plot Charts button draws two charts against depth. One shows N, N60 and (N1)60 together. The other shows the correction factors C and Cn. You can see C rise from 0.75 to 1.00 as the rods lengthen, and Cn fall from 1.70 to 0.72 as stress builds up. The strongest layer in the (N1)60 profile is at 12.00 m, where the value is 28.
STEP 7: SPT CORRELATIONS FOR FRICTION ANGLE
Open the Correlations tab, choose SPT1, depth 1.50 m, and the parameter Friction Angle (Phi). DartiGeo shows the layer type and the inputs it uses: Coarse, effective stress 25.5 kPa, N = 17, N60 = 13, N1(60) = 22.
Every method appears with its value, its notes and its equation. At this depth the results range widely:
- Shioi and Fukui (1982): 30.97
- Meyerhof (1956): 31.86
- Hettiarachchi and Brown (2009), loose sand: 32.17
- Kishida (1967): 33.44
- Muromachi et al. (1974): 34.43
- Bergado et al. (1993): 37.98
- Kulhawy and Mayne (1990): 38.41
- Hatanaka and Uchida (1996): 38.72
- Duncan (2004), sand with Cu below 6: 42.55
- Several other methods return exactly 45.00
- …
The methods use different inputs. Meyerhof uses the raw N, Hatanaka and Uchida use (N1)60, and the Duncan variants use relative density (60.55% from Kulhawy and Mayne) and effective stress. The Notes column shows which inputs each method used, so the choice of methods is visible, not hidden.
Ticking Meyerhof (1956) and Hatanaka and Uchida (1996) gives a statistics row:
- Count 2, minimum 31.86, maximum 38.72
- Average 35.29, standard deviation 4.85, variance 23.53
The engineer decides which methods fit the soil and whether to adopt the average or a lower value for design.
STEP 8: ALLOWABLE BEARING CAPACITY
Switch the parameter to Allowable Bearing Capacity (kPa). These methods are based on the 25 mm allowable settlement, with B = 1.50 m:
- Terzaghi and Peck (1948): 288.11 kPa, using the average uncorrected N over 1B below the footing (N = 19), Cw = 1.00 and Cd = 0.75
- Modified Meyerhof by Bowles (1976): 377.01 kPa, using the average corrected N60 from 0.5B above to 2B below the footing (N60 = 16) and Kd = 1.33
- Anagnostopoulos et al. (1991): 628.34 kPa
- Burland and Burbidge (1985): 835.77 kPa
- …
The spread is nearly threefold, and that is the point. Each method has its own basis, equation and averaging depth, all displayed in the table. Select the method that suits your soil and your local practice. Ticking all four would show a minimum of 288.11, a maximum of 835.77 and an average of about 532 kPa.
STEP 9: GENERATE THE REPORT
Choose the depth and press Report, or use Show Report on the Correlations tab. The report records the correction factors, the methods you ticked, and their results, ready for your calculation package or your reviewer.
WHAT THIS EXAMPLE SHOWS
One borehole produced corrected blow counts, a friction angle with statistics, and a comparison of bearing capacity methods, with every assumption visible in the software.